SOLUTIONS
Q Sine’s integrated solutions are scalable, purpose-built that includes all of the balance of system (BOS) equipment that can be modified to meet the customers’ requirements.
Reactive Power Management Vertical

Offering Holistic Solutions
We offer holistic solutions for the power disturbances, voltage sag and swell, voltage transients & surges, short & long power outages, Harmonics management, PF Control and Reactive power compensation.
- Because of poor PF there is a heavy penalty in the Electricity bill, which is recurring.
- Major loads like DC Drives, Electric pre heating furnaces, Rolling mills creating fluctuating load pattern, generating of higher Harmonic currents and abnormal voltage variations
- Your own CPP (Captive Power Plant like TG or DG) with Light load condition (Floating Grid) creating poor power quality, resulting into penalty
- Due to the presence of number of Non-Linear loads generation of higher Harmonics are inevitable. This leads to increased failure of Electronic cards / PCBs, this also increases the temperature of connected Transformers, Cables, increases Transformer losses etc.
- Unbalance load due to Process, which risks in Power Connection Termination
Industries we serve
Manufacturing
Automobile
Foundry
Hospitals
Packaging
Sugar Mills
Pharma
Datacenters
Textiles
FMCG
Agro Industries
Metal, Mineral & Mines
Case Studies
Sandvik Asia, Pune (End User)
- Load Details : Industrial machines
- Before condition : Initially Current THD was observed to be 15%.
- Solution / Proposal : Proposed 100 Amp AHF - 2 units
- After Solution : Current THD reduced to 6%
Sagar Manufacturers Pvt Ltd (SMPL), Bhopal
- Load Details : Spinning mill machines
- Before condition : Initially Current THD was observed to be 15%
- Solution / Proposal : Proposed 150 Amp AHF - 5 units and 300 Amp AHF - 6 units
- After Solution : Current THD reduced to 7%
Fresenius kabi India Pvt. Ltd, Pune
- Load Details : Machines Application (Pharma)
- Before condition : Power factor was a major concern which was about 0.97
- Solution / Proposal :Proposed 510 KVAR Hybrid panel with 400 KVAR RTPFC & 110 KVAR lead / lag step less power factor correction ( SVG ) Panel
- After Solution : PF improved to 0.995
Sampada Paper Mill, Sangli
- Load Details : Craft paper mill machines
- Before condition :Initially Current THD was observed to be 18% & VTHD 3.2%
- Solution / Proposal : Proposed 200 Amp AHF unit
- After Solution : Current THD reduced to 7% & VTHD reduced to 2.5%
Yash Industries Maharashtra
- Load Details : CNC machines
- Before condition : Power factor concern
- Solution / Proposal : Active correction of PF by SVG
- After Solution : PF improved to 0.995
Kisan Agro, Maharashtra
- Load Details : VFD and motors
- Before condition : Harmonics & Power factor concern
- Solution / Proposal : Active correction of PF by SVG and Harmonics by AHF
- After Solution : PF improved to 0.995 & met IEEE 519:2014 standard for Harmonics