Arc Flash Study Services by Q Sine
Arc Flash Risk Assessment protects employees from electric arc flash hazards in industrial settings.
Q Sine EXPERT SERVICES

Arc Flash Study Services by Q Sine
The core objective of Arc flash studies is to identify and mitigate electrical hazards in your facility. These studies include an arc flash analysis, which calculates the energy that could be released during an arc flash incident. This information is essential for determining appropriate safety measures and personal protective equipment (PPE) requirements.
- Arc Flash Risk Assessment (Study)
- Arc Flash Hazard Labeling Plan
- Site Review / Compliance Assessment
- Mitigation Services
- Single-Line Diagrams
Other Services
Q Sine offers power quality enhancement & power continuity solutions

Annual Maintenance Contracts
We offer our specialised services for the equipment of various Brands and Makes.

Power Quality Audit Service
Q Sine specialises in conducting PQA and makes analysis of the data. Based on which the solution is worked out.

Rental Equipment Services by Q Sine
We offer various Power equipment on rental basis (short and Long duration) to cater your requirement.

Short Circuit / Relay Coordination Study Services by Q Sine
Relay coordination study optimizes protection device settings to minimize faults and ensure reliable power.

Load Flow Analysis Services by Q Sine
Load Flow Analysis ensures proper sizing of cables, transformers, and voltage profile settings.
Industries we serve
Manufacturing
Automobile
Foundry
Hospitals
Packaging
Sugar Mills
Pharma
Datacenters
Textiles
FMCG
Agro Industries
Metal, Mineral & Mines
Case Studies
Sandvik Asia, Pune (End User)
- Load Details : Industrial machines
- Before condition : Initially Current THD was observed to be 15%.
- Solution / Proposal : Proposed 100 Amp AHF - 2 units
- After Solution : Current THD reduced to 6%
Sagar Manufacturers Pvt Ltd (SMPL), Bhopal
- Load Details : Spinning mill machines
- Before condition : Initially Current THD was observed to be 15%
- Solution / Proposal : Proposed 150 Amp AHF - 5 units and 300 Amp AHF - 6 units
- After Solution : Current THD reduced to 7%
Fresenius kabi India Pvt. Ltd, Pune
- Load Details : Machines Application (Pharma)
- Before condition : Power factor was a major concern which was about 0.97
- Solution / Proposal :Proposed 510 KVAR Hybrid panel with 400 KVAR RTPFC & 110 KVAR lead / lag step less power factor correction ( SVG ) Panel
- After Solution : PF improved to 0.995
Sampada Paper Mill, Sangli
- Load Details : Craft paper mill machines
- Before condition :Initially Current THD was observed to be 18% & VTHD 3.2%
- Solution / Proposal : Proposed 200 Amp AHF unit
- After Solution : Current THD reduced to 7% & VTHD reduced to 2.5%
Yash Industries Maharashtra
- Load Details : CNC machines
- Before condition : Power factor concern
- Solution / Proposal : Active correction of PF by SVG
- After Solution : PF improved to 0.995
Kisan Agro, Maharashtra
- Load Details : VFD and motors
- Before condition : Harmonics & Power factor concern
- Solution / Proposal : Active correction of PF by SVG and Harmonics by AHF
- After Solution : PF improved to 0.995 & met IEEE 519:2014 standard for Harmonics